| Req ID | Category | Intent | Legal Status | Name | Subdomain(s) | Context | Conditions | Confidence |
|---|---|---|---|---|---|---|---|---|
| #Q001 | administrative | unknown | mandatory | NPDES Permit Incorporation | wastewater | The Seafood Processing Effluent Guidelines and Standards are incorporated into NPDES permits. | medium | |
| #Q002 | administrative | unknown | guidance | Definitions of Coverage Reference | wastewater | For precise definitions of coverage, see the applicability sections in 40 CFR Part 408. | high | |
| #Q003 | administrative | unknown | mandatory | Effluent Guidelines Applicability | wastewater | The Seafood Processing effluent guidelines apply to preserving and canning facilities in 33 subcategories: | Preserving and canning facilities | high |
| #Q004 | treatment | treatment | mandatory | Alaskan Seafood Processing Grinding Limitations | wastewater | Under 40 CFR Part 408, the limitations for Anchorage, Cordova, Juneau, Ketchikan and Petersburg based upon grinding remain in effect. | Processors in Anchorage, Cordova, Juneau, Ketchikan, and Petersburg | high |
| #Q005 | design | health | mandatory | Source Water Assessment for New Sources | drinking water | As part of permitting new sources, water systems are required a source water assessment for the proposed site. | Permitting of new sources | high |
| #Q006 | operational | health | mandatory | Source Water Assessment Elements | drinking water | The assessment includes: A delineation of the area around a drinking water source through which contaminants might move and reach that drinking water supply; an inventory of possible contaminating activities (PCAs) that might lead to the release of microbiological or chemical contaminants within the delineated area; and a determination of the PCAs to which the drinking water source is most vulnerable. | high | |
| #Q007 | administrative | unknown | mandatory | DWSAP Program Mandate | drinking water | Section 116762.60 of the State Board to develop and implement a program to protect sources of drinking water, specifying that the program must include both a source water assessment program and a wellhead protection program. | high | |
| #Q008 | reporting | reporting | mandatory | Submission of Self-Conducted Assessments | drinking water | Water systems that planned to conduct their own assessments were required to submit their final assessments to DDW no later than December 31, 2002. | Water systems conducting their own assessments | high |
| Req ID | Category | Intent | Legal Status | Name | Subdomain(s) | Limit Type | Limit Value | Context | Conditions | Confidence |
|---|---|---|---|---|---|---|---|---|---|---|
| #R001 | design | operational | mandatory | HU Delineation Scale (CONUS) | other | requirement | 1:24,000 scale | Minimum delineation resolution for the conterminous United States | conterminous United States | high |
| #R002 | design | operational | mandatory | HU Delineation Scale (Hawaii, Pacific basin and the Caribbean) | other | requirement | 1:25,000 scale | Minimum delineation resolution for Hawaii, Pacific basin and the Caribbean | Hawaii, Pacific basin and the Caribbean | high |
| #R003 | design | operational | mandatory | HU Delineation Scale (Alaska) | other | requirement | 1:63,360 scale | Minimum delineation resolution for Alaska | Alaska | high |
| #R004 | design | operational | mandatory | National Hydrologic Unit Boundary Resolution Level | other | requirement | 12 digits | Standard hydrologic unit boundary representation level for the entire United States | entire United States | high |
| #R005 | operational | operational | recommended | Maximum Usage Scale | other | requirement | 1:24,000 scale | Scale limit for identifying hydrographic watershed boundary feature locations | United States | high |
| #R006 | design | operational | guidance | Horizontal Positional Accuracy (Inherent Error) | other | requirement | +/- 40 feet | Assumed minimum inherent error based on 1:24,000-scale source data | Mapped at approximately 1:24,000-scale | high |
| #R007 | design | operational | mandatory | Latitude Resolution | other | requirement | 1.0E-5 Decimal degrees | Geographic coordinate system latitude resolution | high | |
| #R008 | design | operational | mandatory | Longitude Resolution | other | requirement | 1.0E-5 Decimal degrees | Geographic coordinate system longitude resolution | high |
| Req ID | Category | Name | Context | Confidence |
|---|---|---|---|---|
| #D001 | Undisinfected secondary recycled water | oxidized wastewater. | high | |
| #D002 | Disinfected secondary-23 recycled water | recycled water that has been oxidized and disinfected so that the median concentration of total coliform bacteria in the disinfected effluent does not exceed a most probable number (MPN) of 23 per 100 milliliters utilizing the bacteriological results of the last seven days for which analyses have been completed, and the number of total coliform bacteria does not exceed an MPN of 240 per 100 milliliters in more than one sample in any 30 day period. | high | |
| #D003 | Disinfected secondary-2.2 recycled water | recycled water that has been oxidized and disinfected so that the median concentration of total coliform bacteria in the disinfected effluent does not exceed a most probable number (MPN) of 2.2 per 100 milliliters utilizing the bacteriological results of the last seven days for which analyses have been completed, and the number of total coliform bacteria does not exceed an MPN of 23 per 100 milliliters in more than one sample in any 30 day period. | high | |
| #D004 | Disinfected tertiary recycled water | a filtered and subsequently disinfected wastewater. The filtration process must meet the criteria described in §60301.320 (a) or (b). The disinfection process must meet the criteria described in §60301.230(a)(1) or (2). The median concentration of total coliform bacteria measured in the disinfected effluent must not exceed an MPN of 2.2 per 100 milliliters utilizing the bacteriological results of the last seven days for which analyses have been completed and the number of total coliform bacteria does not exceed an MPN of 23 per 100 milliliters in more than one sample in any 30 day period. No sample shall exceed an MPN of 240 total coliform bacteria per 100 milliliters. | high | |
| #D005 | CCR | California Code of Regulations | high | |
| #D006 | DWSRF | Drinking Water State Revolving Fund | high | |
| #D007 | The Purple Book | Compilations of recycled water-related laws | high | |
| #D008 | CLIP | California Laboratory Intake Portal | high | |
| #D009 | EAR | Electronic Annual Reports | high | |
| #D010 | ELAP | Environmental Laboratory Accreditation Program | high | |
| #D011 | CCRs | Consumer Confidence Reports | high | |
| #D012 | PFAS | Per- and Polyfluoroalkyl Substances | high |