Document ID us-ca-swpnlsc-2025-02-28-4 Title Storm Water Program: Numeric List of SIC Codes URL https://www.waterboards.ca.gov/water_issues/programs/stormwater/sicnum.html Jurisdiction /us/ca Subdomain(s) none Language Status completed Analyzed at 2026-05-12 05:01:57.119541+00:00 Relevance inventory_targeted_fetch

Q Qualitative Requirements (9)

Req ID Category Intent Legal Status Name Subdomain(s) Context Conditions Confidence
#Q001administrativeunknownrecommendedEvaluating SIC Code Permit CoverageotherWhen evaluating whether a facility is required to obtain coverage under the Industrial General Permit on the basis of its SIC code, please consider any applicable footnote at the bottom of this webpage.When evaluating whether a facility is required to obtain coverage based on its SIC codehigh
#Q002administrativeunknownguidanceRegional Board Discretionary Permit Coverage RequirementsotherAdditionally, per Industrial General Permit section XIX and Code of Federal Regulations, title 40, section 122.26(a)(9)(i)(D), a Regional Water Quality Control Board may require a facility to obtain permit coverage even if it is not otherwise required to do so if the Regional Water Quality Control Board determines that the facility’s discharge contributes to a violation of water quality standards or is a significant contributor of pollutants to waters of the United States.If the Regional Water Quality Control Board determines that the facility's discharge contributes to a violation of water quality standards or is a significant contributor of pollutants to waters of the United Stateshigh
#Q003administrativeunknownmandatoryLivestock and Agricultural Facility Coverage ScopeotherThe facility is regulated only if it has other activities on-site that are subject to the requirements of 40 Code of Federal Regulations, Chapter I, Subchapter N, Part 412, Subparts A, C, or D. Only the portions of the facility involved in those activities are regulated.Facilities classified under specific general livestock or agricultural SIC codes (Footnote 2)high
#Q004administrativeunknownguidanceMining Facilities Coverage ExemptionsotherFacilities not regulated by the Industrial General Permit include (1) areas of coal mining operations no longer meeting the definition of a reclamation area under 40 Code of Federal Regulations 434.11(1) because the performance bond issued to the facility by the appropriate Surface Mining Control and Reclamation Acts authority has been released; (2) areas of non-coal mining operations which have been released from applicable State or Federal reclamation requirements after December 17, 1990; (3) sites where mining claims are being maintained prior to disturbances associated with the extraction, beneficiation, or processing of mined material; and (4) sites where minimal activities are undertaken for the sole purpose of maintaining a mining claim.Facilities classified under specific oil, gas, or mining SIC codes (Footnote 5)high
#Q005administrativeunknownmandatoryTransportation Facilities Coverage ScopeotherThe facility is regulated only if it has vehicle maintenance shops, equipment cleaning operations, or airport deicing operations, and only the portions of the facility involved in vehicle maintenance (including vehicle rehabilitation, mechanical repairs, painting, fueling, and lubrication) are regulated.Facilities classified under specific transportation SIC codes (Footnote 6)high
#Q006administrativeunknownmandatorySteam Electric Power Generating Facilities CoverageotherOnly facilities that generate steam for electric power through the combustion of coal, oil, wood, etc. are regulated by the Industrial General Permit.Facilities classified under Electric Services SIC code 4911 (Footnote 7)high
#Q007administrativeunknownmandatorySewage or Wastewater Treatment Works Coverage Criteriawastewater, otherThe facilities regulated by the Industrial General Permit are facilities used in the storage, treatment, recycling, and reclamation of municipal or domestic sewage, including land dedicated to the disposal of sewage sludge, that are located within the confines of the facility, with a design flow of one million gallons per day or more, or required to have an approved pretreatment program under 40 Code of Federal Regulations part 403.Facilities classified under Sewerage Systems SIC code 4952 (Footnote 8)high
#Q008administrativeunknownmandatoryRefuse Systems Coverage ConditionsotherFacilities classified under this SIC code are regulated by the Industrial General Permit if they conduct activities described in the Industrial General Permit, Attachment A, category 4, “Hazardous Waste Treatment, Storage, or Disposal Facilities,” or category 5 “Landfills, Land Application Sites, and Open Dumps.”Facilities classified under Refuse Systems SIC code 4953 (Footnote 9)high
#Q009administrativeunknownmandatoryRecycling Facilities Coverage ScopeotherOnly facilities involved in the recycling of materials, including metal scrapyards, battery reclaimers, salvage yards, and automobile junkyards are regulated by the Industrial General Permit.Facilities classified under Recycling Facilities SIC codes 5015 or 5093 (Footnote 10)high

P Quantitative Requirements (1)

Req ID Category Intent Legal Status Name Subdomain(s) Limit Type Limit Value Context Conditions Confidence
#P001designoperationalmandatorydesign flowwastewaterrequirement>= 1 million gallons per dayApplicability for Sewage or Wastewater Treatment Works (facilities used in the storage, treatment, recycling, and reclamation of municipal or domestic sewage)Located within the confines of the facilityhigh

D Definitions (17)

Req ID Category Name Context Confidence
#D001DivisionDivision of Water Rightshigh
#D002CEQACalifornia Environmental Quality Acthigh
#D003PolicyPolicy for Maintaining Instream Flows in Northern California Coastal Streamshigh
#D004CDACumulative Diversion Analysishigh
#D005SICStandard Industrial Classificationhigh
#D006OSHAOccupational Safety & Health Administrationhigh
#D007NAICSNorth American Industrial Classification Systemhigh
#D008QSD/QSPConstruction General Permit Qualified SWPPP Developer/Qualified SWPPP Practitionerhigh
#D009Category 4hazardous waste treatment, storage, or disposal facilities, including any facility operating under interim status or a general permit under Subtitle C of the Federal Resource, Conservation, and Recovery Acthigh
#D010Category 5landfills, land application sites, and open dumps that receive or have received industrial waste from any facility within any other category in Attachment A; including facilities subject to regulation under Subtitle D of the Federal Resource, Conservation, and Recovery Act, and facilities that have accepted wastes from construction activitieshigh
#D011construction activitiesany clearing, grading, or excavation that results in disturbancehigh
#D012CalGEMCalifornia Geologic Energy Management Divisionhigh
#D013Class II UIC wellswells used to inject fluids that are associated with oil and natural gas production operations into the subsurfacehigh
#D014MOAMemorandum of Agreementhigh
#D015State Water BoardState Water Resource Control Boardhigh
#D016Water BoardsState and Regional Water Boardshigh
#D017UICUnderground Injection Controlhigh