Parameter Viewer

Document ID ca-on-toronto-tiii-2022-03-28 Title Tier III - Work Instructions – Completion of the Canadian Ballast Water Reporting Form URL https://www.toronto.ca/legdocs/mmis/2025/ie/bgrd/backgroundfile-255787.pdf Jurisdiction /ca/on/toronto Subdomain(s) none Language Status completed Analyzed at 2026-05-12 03:35:28.692644+00:00 Relevance inventory_targeted_fetch

Q Qualitative Requirements (36)

Req ID Category Intent Legal Status Name Subdomain(s) Context Conditions Confidence
#Q001designhealthmandatoryBackflow Prevention Device Installationdrinking waterThe Water Supply By-law protects the integrity of Toronto's drinking water distribution system by requiring the installation and maintenance of backflow prevention devices at ICI and multi-residential properties.Applicable to ICI (industrial, commercial, and institutional) and multi-residential properties.high
#Q002administrativetreatmentmandatoryPollution Prevention Plans ImplementationwastewaterThe Sewers By-law sets strict concentration limits and requires industries to implement Pollution Prevention Plans.Applicable to industries under the Sewers By-law.high
#Q003treatmenttreatmentmandatoryAmalgam Separator InstallationwastewaterFor example, dental offices must install amalgam separators to prevent mercury and other metal particles from entering the sewer system.Applicable to dental offices.high
#Q004reportingreportingmandatoryCompliance Agreement Monitoring and ReportingwastewaterThe agreement is designed to ensure that the company achieves compliance by the conclusion of the agreement and includes a requirement for regular sampling and progress reporting to the City.Applicable to companies temporarily permitted to exceed by-law discharge limits under an approved Compliance Agreement.high
#Q005reportingreportingmandatoryPollution Prevention (P2) Plan SubmissionwastewaterThis program requires industries discharging any amount of the 33 subject pollutants identified in the Sewers By-law to submit and maintain a P2 Plan until that business continually meets the requirements of and is participating in a Best Management Practices plan (BMP).Applicable to industries discharging any amount of the 33 subject pollutants identified in the Sewers By-law.high
#Q006monitoringhealthmandatoryRecreational Water E. coli Monitoringrecreational waterSeven days a week, from late May to Labour Day, water samples are taken at each of the City's ten supervised beaches and analyzed for E. coli levels.Conducted seven days a week from late May to Labour Day at each of the ten supervised beaches.high
#Q007reportingreportingmandatoryRecreational Water Public Health Reportingrecreational waterResults are forwarded to Toronto Public Health, which determines if beaches should be posted as safe for swimming or not.Applicable after E. coli monitoring results are obtained from the supervised beaches.high
#Q008designoperationalmandatoryEffluent Sampling Facility InstallationwastewaterThe owner of a plant shall, for each type of effluent deposited by the plant, install and maintain facilities, including sampling connections and flow measuring devices, of such type as the Minister may in writing approve for sampling and analysing effluents for the purpose of enabling the Minister to determine whether the owner is complying with the limits of authorized deposits prescribed by section 5Applicable to all owners of new or expanded plants depositing deleterious substances.high
#Q009operationaloperationalmandatoryComposite Sample Collection MethodwastewaterA composite sample shall be obtained by collecting effluent discharged from a plant during a processing day (a) continually during a sampling period of 24 hours at a rate in proportion to the flow rate of the effluent discharged; or (b) in such a manner that equal volumes of effluent are delivered into a receptacle at equal intervals not longer than one hour during a sampling period of 24 hours.Applicable when taking the regular samples required by section 8.high
#Q010monitoringoperationalmandatorySampling Frequency RequirementwastewaterThe sampling referred to in paragraph 6(b) shall be made (a) in the case of a plant where the weekly quantity of raw potatoes processed is less than 400 tonnes, on one processing day each week; and (b) in the case of a plant where the weekly quantity of raw potatoes processed is 400 tonnes or more, on two processing days each week.Weekly processing volume determines if sampling occurs once or twice per week.high
#Q011monitoringtreatmentmandatoryAdherence to Standard Analytical ProcedureswastewaterFor the purposes of paragraph 6(c), procedures pertaining to sampling, preservation and storage of samples and prevention of interference relating to the test methods referred to in paragraph (1)(a), as outlined in the general sections of the publication Standard Methods for the Examination of Water and Waste Water, 14th edition (1975), published jointly by the American Public Health Association, American Water Works Association and the Water Pollution Control Federation, shall be adhered to.Applies to all required effluent analysis for BOD and TSS.high
#Q012monitoringoperationalmandatoryContinuous Flow RecordingwastewaterFor the purpose of paragraph 6(d), the flow of each type of effluent deposited by a plant shall be measured continuously and recorded.Applies to every type of effluent deposited by the plant.high
#Q013reportingreportingmandatoryMonthly Compliance ReportingwastewaterThe owner of a plant shall, within 30 days after the end of each month, sign, date and forward to the Minister a report, in such form as the Minister may in writing approve, showing for that month [actual daily deposits, average daily deposits, pH, production data, and total daily flow].Must be submitted within 30 days of month end.high
#Q014reportingreportingmandatoryInitial Production DeclarationwastewaterThe owner of a new plant shall, before he deposits any deleterious substance prescribed by section 4, and the owner of an expanded plant shall, within 30 days of becoming subject to these Regulations, sign, date and forward to the Minister a declaration... showing the projected weekly production... showing the projected annual production... and listing the major products produced.Applies to new plants before deposit or expanded plants within 30 days of expansion trigger.high
#Q015reportingreportingmandatoryAnnual Production DeclarationwastewaterThe owner of a plant shall, within 30 days after the end of each calendar year, sign, date and forward to the Minister a declaration, in such form as the Minister may in writing approve, showing the actual production of the plant for the previous year in terms of tonnes of raw potatoes processed.Required annually by January 30th for the previous calendar year.high
#Q016operationaltreatmentmandatoryAuthorized pH Rangewastewaterthe pH of each composite sample of effluent, determined in accordance with subsection 9(3), is between 6.0 and 9.0.Conditional requirement for the authorized deposit of deleterious substances.high
#Q017reportingreportingmandatorySpill Reporting to General Managerwastewater, otherFailure to report a spill to the General Manager.In the event of a spill incident.high
#Q018administrativeoperationalmandatoryPrivate Water Source Discharge Agreements and PermitswastewaterThe City enters into agreements and permits with applicants and property owners who draw from private water sources (e.g. groundwater) and discharge into the City sanitary, combined, or storm sewers.Applies to property owners drawing from private water sources (e.g. groundwater) discharging into the City sewer system.high
#Q019treatmenttreatmentmandatoryGrease Interceptor InstallationwastewaterFailure to install a grease interceptor.Applicable to relevant commercial facilities such as restaurants as identified under the Sewers By-Law.high
#Q020designoperationalmandatoryWater Meter Installationdrinking waterFailure to have a water meter installed.Applicable to properties under the Water Supply By-law.high
#Q021operationaltreatmentmandatoryStorm Sewer Discharge Quality Standardswastewater, otherDischarges into storm sewers, which flow into watercourses, rivers, and Lake Ontario, are not subject to a fee but must meet specific quality and quantity requirements.Applicable to all discharges into the municipal storm sewer system.high
#Q022designhealthmandatoryBackflow Prevention Device Installationdrinking waterThe Water Supply By-law protects the integrity of Toronto's drinking water distribution system by requiring the installation and maintenance of backflow prevention devices at ICI and multi-residential properties.Applicable to ICI and multi-residential propertieshigh
#Q023administrativetreatmentmandatoryPollution Prevention Plans ImplementationwastewaterThe Sewers By-law sets strict concentration limits and requires industries to implement Pollution Prevention Plans.Applicable to industries under the Sewers By-lawhigh
#Q024treatmenttreatmentmandatoryAmalgam Separator Installationwastewaterdental offices must install amalgam separators to prevent mercury and other metal particles from entering the sewer system.Applicable to dental officeshigh
#Q025reportingreportingmandatoryPollution Prevention (P2) Plan SubmissionwastewaterThis program requires industries discharging any amount of the 33 subject pollutants identified in the Sewers By-law to submit and maintain a P2 Plan until that business continually meets the requirements of and is participating in a Best Management Practices plan (BMP).Applicable to industries discharging any of the 33 subject pollutantshigh
#Q026reportingreportingmandatoryCompliance Agreement Monitoring and ReportingwastewaterThe agreement is designed to ensure that the company achieves compliance by the conclusion of the agreement and includes a requirement for regular sampling and progress reporting to the City.Applicable to companies under an approved Compliance Agreementhigh
#Q027monitoringhealthmandatoryRecreational Water E. coli Monitoringrecreational waterSeven days a week, from late May to Labour Day, water samples are taken at each of the City's ten supervised beaches and analyzed for E. coli levels.City supervised beaches from late May to Labour Dayhigh
#Q028reportinghealthmandatoryRecreational Water Health Advisory Thresholdrecreational waterToronto's beaches are posted advising against swimming if E. coli levels exceed 100 cfu per 100mL of water.When E. coli levels exceed 100 cfu/100mLhigh
#Q029operationaltreatmentmandatoryStorm Sewer Discharge Quality Requirementswastewater, otherDischarges into storm sewers, which flow into watercourses, rivers, and Lake Ontario, are not subject to a fee but must meet specific quality and quantity requirements.All discharges into storm sewershigh
#Q030treatmentoperationalmandatoryGrease Interceptor Installation DutywastewaterFailure to install a grease interceptor.Applicable to relevant commercial facilities under Sewers By-lawhigh
#Q031reportingreportingmandatorySpill Reporting Dutywastewater, otherFailure to report a spill to the General Manager.Mandatory following a spill eventhigh
#Q032administrativeoperationalmandatoryPrivate Water Discharge PermitswastewaterDischarging private water to the storm sewer system without an agreement or permit.Applies to property owners drawing from private sources like groundwaterhigh
#Q033designoperationalmandatoryWater Meter Installation Dutydrinking waterFailure to have a water meter installed.Applicable to properties under the Water Supply By-lawhigh
#Q034corrective_actionoperationalmandatoryCompliance with Orders to ComplywastewaterDepending on the circumstances, the violator may be given time to resolve the issue voluntarily or, if immediate action is needed, issued an Order to Comply requiring prompt corrective measures.Applicable when a violation is identified and immediate corrective action is deemed necessary by Toronto Water staff.high
#Q035administrativeoperationalmandatoryIndustrial Waste Surcharge Fee PaymentwastewaterThe results determine the fees the company must pay the City for treating excess discharge above the By-law limits.Applicable to businesses exceeding sanitary sewer discharge limits for BOD, TSS, TP, Phenols, or TKN under an Industrial Waste Surcharge Agreement.high
#Q036operationaloperationalmandatoryCompliance Agreement Condition AdherencewastewaterFailure to meet the conditions outlined in the agreement may result in its termination.Applicable to companies operating under an approved Compliance Agreement while undertaking upgrades.high

P Quantitative Requirements (1)

Req ID Category Intent Legal Status Name Subdomain(s) Limit Type Limit Value Context Conditions Confidence
#P001microbiologicalhealthguidanceE. colirecreational waterrequirement> 100 cfu per 100mLToronto's beaches are posted advising against swimming if E. coli levels exceed 100 cfu per 100mL of water.Seven days a week, from late May to Labour Dayhigh

D Definitions (30)

Req ID Category Name Context Confidence
#D001biosolidsthe nutrient rich organic materials produced during the treatment of wastewaterhigh
#D002outfallsthe point where municipal storm sewers exit into the environment via the city's waterwayshigh
#D003WWTWastewater Treatment Installedhigh
#D004P2Pollution Preventionhigh
#D005IWSAIndustrial Waste Surcharge Agreementhigh
#D006BODBiological Oxygen Demandhigh
#D007TSSTotal Suspended Solidshigh
#D008TPTotal Phosphoroushigh
#D009TKNTotal Kjeldahl Nitrogenhigh
#D010BMPBest Management Practices planhigh
#D011OMPOutfall Monitoring Programhigh
#D012CaSRCanadian Surface Reanalysishigh
#D013dischargeflowhigh
#D014Sewers By-lawMunicipal Code Chapter 681high
#D015Water Supply By-lawMunicipal Code Chapter 851high
#D016ICIindustrial, commercial, and institutionalhigh
#D017Blue Flag Programcertifies beaches as "Blue Flag" if they meet standards for water quality, safety, environmental education and information, the provision of services, and other environmental criteriahigh
#D018RAPRemedial Action Planhigh
#D019E. coliEscherichia colihigh
#D020Compliance Agreementpermits businesses whose discharge are non-compliant with the by-law parameter limits to submit a compliance plan application to the General Managerhigh
#D021high priorityoutfalls indicating possible sanitary cross connectionshigh
#D022Convictionsmay include multiple prosecutions for a company or individual and may include prosecution files initiated in prior years and concluded in 2024high
#D023Withdrawn where charges laidCharges that were laid and later withdrawn following a global resolution with a similarly charged or jointly charged company having been convicted.high
#D0244AAPPhenolicshigh
#D025PMRAPest Management Regulatory Agencyhigh
#D026NLSnoxious liquid substanceshigh
#D027IBC CodeInternational Code for the Construction and Equipment of Ships Carrying Dangerous Chemicals in Bulkhigh
#D028BCH CodeCode for the Construction and Equipment of Ships Carrying Dangerous Chemicals in Bulkhigh
#D029Pollution ConventionInternational Maritime Organization's Pollution Conventionhigh
#D030Annex IIRegulations for the Control of Pollution by Noxious Liquid Substances in Bulkhigh