Parameter Viewer

Document ID ca-on-toronto-mtdsf-null-2 Title Manufactured Treatment Device Summary Form URL https://www.toronto.ca/wp-content/uploads/2023/01/84d5-SubReq-MTD-Summary-Form-19Jan23.pdf Jurisdiction /ca/on/toronto Subdomain(s) none Language Status completed Analyzed at 2026-05-12 03:25:48.482074+00:00 Relevance inventory_targeted_fetch

Q Qualitative Requirements (16)

Req ID Category Intent Legal Status Name Subdomain(s) Context Conditions Confidence
#Q001administrativereportingmandatoryMTD Summary Form Completion and SubmissionotherNote: MTD Summary Form to completed in accordance with Design Criteria for MTDs and appended as part of Stormwater Management Reporthigh
#Q002designtreatmentmandatoryMTD Scaling ProvisionsotherScaling Provisions Met [applicable where proposed model is not the same as tested model]Applicable where proposed model is not the same as tested modelhigh
#Q003designtreatmentmandatoryMTD Internal Bypass CapacityotherInternal By-pass Capacity > Inlet Pipe Capacity minus 90% Annual Rainfall Flow Ratehigh
#Q004designtreatmentmandatoryInline OGS Maximum Scour ConcentrationotherMaximum Scour Concentration at Maximum Tested Scour Flow Rate <= 25mg/Lhigh
#Q005designtreatmentmandatoryOGS Sediment Storage Capacityother[For OGS] Provided MTD Storage Capacity > Annual Sediment Loading Volumehigh
#Q006designtreatmentmandatoryInline OGS Scour Bypass CapacityotherInternal By-pass Capacity > Inlet Pipe Capacity minus Maximum Scour Flow RateApplicable for Option A. Inline OGS configurationhigh
#Q007designtreatmentmandatoryOff-line MTD Diversion CapacityotherDiversion By-pass Capacity > Inlet Pipe Capacity minus 90% Annual Rainfall Flow RateApplicable for Option C. Off-line OGS or Filter configurationhigh
#Q008designtreatmentmandatoryOGS Verification Standardother[For OGS] Canada ETV OGS Lab Protocol + ISO 14034: ETV VerificationRequired verification protocol for Oil-Grit Separatorshigh
#Q009operationaloperationalmandatoryFilter Device Maintenance Interval Specificationother[For Filter Device] Manufacturer Designed and Recommended Maintenance IntervalRequired for filter device operations and maintenance reportinghigh
#Q010designtreatmentmandatoryFilter Device Verification (TAPE Certification)other[For Filter Device] TAPE Field Test Protocol 1 + TAPE CertificationApplicable for Filter Device verificationhigh
#Q011designtreatmentmandatoryFilter Device Verification (TAPE + ISO 14034)other[For Filter Device] TAPE Field Test Protocol 1 + ISO 14034: ETV VerificationApplicable for Filter Device verificationhigh
#Q012administrativereportingmandatorySubmission of MTD Engineering DrawingsotherMTD Engineering DrawingsTo be appended as part of Stormwater Management Reporthigh
#Q013administrativereportingmandatorySubmission of Verification Statements/Certification ReportotherVerification Statements/Certification ReportTo be appended as part of Stormwater Management Reporthigh
#Q014administrativereportingmandatorySubmission of MTD Sizing and Performance Calculation SheetotherMTD Sizing and Performance Calculation SheetTo be appended as part of Stormwater Management Reporthigh
#Q015administrativereportingmandatorySubmission of Hydraulic Calculations for InstallationotherHydraulic Calculations for Inline/Offline InstallationTo be appended as part of Stormwater Management Reporthigh
#Q016administrativereportingmandatorySubmission of Operations & Maintenance ManualotherOperations & Maintenance ManualTo be appended as part of Stormwater Management Reporthigh

P Quantitative Requirements (6)

Req ID Category Intent Legal Status Name Subdomain(s) Limit Type Limit Value Context Conditions Confidence
#P001designtreatmentmandatoryMaximum Scour Concentrationotherrequirement<= 25 mg/LInstallation Configuration - Option A. Inline OGSat Maximum Tested Scour Flow Ratehigh
#P002designtreatmentmandatoryAnnual Rainfall Volume Captureothertreatment_goal90 %Design Treatment Flowhigh
#P003designoperationalmandatoryCapture eventsotherrequirement>= 3 eventsIncludes capture of min 3 events with rainfall intensity and depth corresponding to 90% average annual rainfall volumeSWM Report requirementmedium
#P004designoperationalmandatoryDesign intensitiesotherrequirement10 to 100 %Calculated range for design intensities corresponding from 10% to 100% of Annual Rainfall Volume Capturedmedium
#P005designtreatmentmandatoryMaximum Treatment Depth Calculation Factorotherrequirement50 %Maximum Treatment Depth = Chamber Depth minus 50% of Maximum Sediment Storage DepthCalculation criteria for MTD characteristicshigh
#P006designtreatmentmandatoryInternal By-pass Capacity Thresholdotherrequirement90 %Internal By-pass Capacity > Inlet Pipe Capacity minus 90% Annual Rainfall Flow RateApplicable to Inline OGS, Inline Filter, and Off-line configurationshigh

D Definitions (21)

Req ID Category Name Context Confidence
#D001TAPE Field Test Protocol 1Includes capture of min 3 events with rainfall intensity and depth corresponding to 90% average annual rainfall volumehigh
#D002Chamber depthChamber depth is measured from the outlet invert to the bottom of the device.high
#D003Maximum Treatment DepthMaximum Treatment Depth = Chamber Depth minus 50% of Maximum Sediment Storage Depthhigh
#D004Sediment Storage CapacityMeasured from the bottom of the device to manufacturer-recommended sediment cleanout depthhigh
#D005Design intensitiesCalculated range for design intensities corresponding from 10% to 100% of Annual Rainfall Volume Capturedhigh
#D006MTDManufactured Treatment Devicehigh
#D007SWMStormwater Managementhigh
#D008OGSOil-Grit Separatorhigh
#D009TAPE Field Test ProtocolIncludes capture of min 3 events with rainfall intensity and depth corresponding to 90% average annual rainfall volumehigh
#D010Acceptance itemsFor the purpose of the Wellness Report the Acceptance items are required post-construction when the infrastructure is put into service. Acceptance is required to start the warranty period.high
#D011Assumption itemsFor the purpose of the Wellness Report the Assumption items are required at the end of the warranty period in order for the City to assume ownership of the infrastructure.high
#D012Submission Documentsdigital PDF of the completed Wellness Report including attachmentshigh
#D013MECPMinistry of Environment, Conservation and Parkshigh
#D014CLI ECAConsolidated Linear Infrastructure Environmental Compliance Approvalhigh
#D015DWWPDrinking Water Works Permithigh
#D016ECSEngineering & Construction Serviceshigh
#D017NFPANational Fire Protection Associationhigh
#D018NASSCONational Association of Sewer Service Companieshigh
#D019PACPPipeline Assessment Certification Programhigh
#D020MTDsManufacturer Treatment Deviceshigh
#D021ECAEnvironmental Compliance Approvalhigh