Parameter Viewer

Document ID ca-on-toronto-mtdsf Title Manufactured Treatment Device Summary Form URL https://www.toronto.ca/wp-content/uploads/2023/01/8e88-Dry-Cleaner-and-Commercial-Laundry-P2-Plan-FormEditable-FINAL.pdf Jurisdiction /ca/on/toronto Subdomain(s) none Language Status completed Analyzed at 2026-05-12 03:25:59.988906+00:00 Relevance inventory_targeted_fetch

Q Qualitative Requirements (23)

Req ID Category Intent Legal Status Name Subdomain(s) Context Conditions Confidence
#Q001reportingreportingmandatoryP2 Plan Submission and RetentionwastewaterA completed Plan must be submitted to Toronto Water every six years and a copy kept at the facility for inspection by the City.Every six yearshigh
#Q002operationaloperationalmandatoryFederal Tetrachloroethylene Regulations CompliancewastewaterWhere current technology does not allow product substitution, we will support the P2 process by complying with Environment Canada's Tetrachloroethylene (Use in Dry Cleaning and Reporting Requirements) Regulations and follow the Compliance Guide for Dry Cleaners.Where current technology does not allow product substitutionhigh
#Q003operationaloperationalrecommendedSurfactant Product Substitution InquirywastewaterContact the product supplier for information and ask to substitute any product containing these chemicals to products with no (or less) content of NPs and NPEs.high
#Q004prohibitiontreatmentrecommendedIndustrial Uniform Wash ProhibitionwastewaterCommercial laundry facility should not wash industrial uniforms that are contaminated with oil, grease and other regulated chemicals, such as contaminated uniforms from automotive garages, restaurants, etc., unless the wastewater is treated to prevent such oil, grease and other regulated chemicals from entering into public sewage works.Unless the wastewater is treated to prevent regulated chemicals from entering public sewage workshigh
#Q005prohibitionoperationalmandatoryChemical Waste Disposal and ProhibitionwastewaterAll scrap, expired and off-specification chemicals, including acids, bases and other volatile petroleum based cleaning chemicals, should be sent to a Ministry of the Environment (MOE) registered waste disposal company/site for proper disposal. Do not pour / discharge such chemicals directly / indirectly into public sewage works.high
#Q006operationaltreatmentguidanceChloroform Concentration Reduction OptionswastewaterTo reduce Chloroform concentration, will you consider the following: Separate materials that require bleach; Use automatic dosing; Reduce dosing; Identify alternatives; Train staff on proper bleach usage.high
#Q007operationaloperationalmandatoryWastewater and Residue Transport FrequencywastewaterWastewater and/or Residue are transported to a waste management facility no less than once every 12 monthshigh
#Q008administrativeoperationalmandatoryEmployee Awareness and InvolvementwastewaterEmployee Awareness and Involvement - Management will communicate the requirements of this Pollution Prevention Plan to all employees.high
#Q009administrativeoperationalmandatoryPollution Prevention Program Employee InvolvementwastewaterProgram's Success - This requires the support and commitment of management and staff. Management will solicit from employees new ideas regarding pollution prevention and preparation of future Pollution Prevention Plans.high
#Q010operationaloperationalmandatoryGood Housekeeping PracticeswastewaterGood Housekeeping - Good housekeeping practices will be maintained for minimizing the risk of spillage and loss of solvents and chemicals.high
#Q011corrective_actionoperationalmandatorySpill Containment and Response ProgramwastewaterSpill Containment and Response - A program that ensures releases do not enter the drain will be maintained. Furthermore, procedures that identify spill response procedures will be posted.high
#Q012administrativeoperationalmandatorySupplier Chemical Reduction RequestswastewaterRequest to the supplier - Requests will be made to the suppliers/manufacturers to take steps necessary to investigate the opportunity for reduction, replacement or possible elimination of chemical solvents.high
#Q013administrativereportingmandatoryInspection Availability UndertakingwastewaterI undertake to comply with this Plan and make it readily available for inspection at the subject premises by the representatives of the City of Toronto.high
#Q014reportingreportingmandatorySupporting Documentation ProvisionwastewaterPlease provide supporting documentation, such as subject pollutant information from suppliers (not MSDS) and sample results used in the calculation in the submission of this Pollution Prevention (P2) Plan.high
#Q015administrativereportingmandatoryMTD Summary Form CompletionotherMTD Summary Form to completed in accordance with Design Criteria for MTDs and appended as part of Stormwater Management Reporthigh
#Q016designoperationalmandatoryInline OGS Bypass CapacityotherInternal By-pass Capacity > Inlet Pipe Capacity minus 90% Annual Rainfall Flow Rate; and Internal By-pass Capacity > Inlet Pipe Capacity minus Maximum Scour Flow RateOption A. Inline OGShigh
#Q017designtreatmentmandatoryInline OGS Maximum Scour ConcentrationotherMaximum Scour Concentration at Maximum Tested Scour Flow Rate <= 25mg/LOption A. Inline OGShigh
#Q018designoperationalmandatoryInline Filter Bypass CapacityotherInternal By-pass Capacity > Inlet Pipe Capacity minus 90% Annual Rainfall Flow RateOption B. Inline Filterhigh
#Q019designoperationalmandatoryOff-line MTD Bypass CapacityotherDiversion By-pass Capacity > Inlet Pipe Capacity minus 90% Annual Rainfall Flow RateOption C. Off-line OGS or Filterhigh
#Q020designoperationalmandatoryOGS Storage Capacity Requirementother[For OGS] Provided MTD Storage Capacity > Annual Sediment Loading VolumeFor Oil-Grit Separator (OGS) installationshigh
#Q021designoperationalmandatoryMTD Scaling ProvisionsotherScaling Provisions MetApplicable where proposed model is not the same as tested modelhigh
#Q022administrativereportingmandatoryMTD Testing and Certification ProtocolsotherMTD must meet one of the following protocols: [For OGS] Canada ETV OGS Lab Protocol + ISO 14034: ETV Verification; [For Filter Device] TAPE Field Test Protocol 1 + TAPE Certification; [For Filter Device] TAPE Field Test Protocol 1 + ISO 14034: ETV VerificationRequirement to select the applicable certification protocol for the device typehigh
#Q023reportingreportingmandatorySWM Report Mandatory AttachmentsotherThe following items must be attached with the Stormwater Management (SWM) Report: MTD Engineering Drawings, Verification Statements/Certification Report, MTD Sizing and Performance Calculation Sheet, Hydraulic Calculations for Inline/Offline Installation, and Operations & Maintenance Manual.Selection of all applicable documents required for submissionhigh

P Quantitative Requirements (9)

Req ID Category Intent Legal Status Name Subdomain(s) Limit Type Limit Value Context Conditions Confidence
#P001chemicaltreatmentmandatoryNonylphenols (NPs)wastewaterMAC<= 0.02 mg/Ldischarged into the municipal sanitary sewer systemshigh
#P002chemicaltreatmentmandatoryNonylphenol Ethoxylates (NPEs)wastewaterMAC<= 0.2 mg/Ldischarged into the municipal sanitary sewer systemshigh
#P003chemicaltreatmentunknownChloroformwastewaterrequirement> 0.04 mg/Lfinal effluentIf Yes, please state your Pollution Prevention Option to reduce Chloroform concentrationmedium
#P004designoperationalunknownSecondary containment capacityotherrequirement>= 110 %capacity of the largest tank or container within the containment systemencompassing at least the entire surface under each dry cleaning machine, tank, or other container containing tetrachloroethylene, wastewater, or residuehigh
#P005physicaltreatmentmandatoryMaximum Scour Concentrationwastewaterrequirement<= 25 mg/LMaximum Scour Concentration at Maximum Tested Scour Flow Rate for Inline OGS installationApplicable to Installation Configuration Option A (Inline OGS)high
#P006designtreatmentmandatoryAnnual Rainfall Volume Capturewastewaterrequirement90 %Standard design treatment flow capture target for filters and bypass calculationsApplicable to sizing, performance evaluation, and bypass capacity calculations for Options A, B, and Chigh
#P007designoperationalmandatoryMaximum Treatment Depth Calculation Factorwastewaterrequirement50 %Maximum Treatment Depth = Chamber Depth minus 50% of Maximum Sediment Storage Depthhigh
#P008designoperationalmandatoryAnnual Rainfall Volume Captured Design Rangewastewaterrequirement10 to 100 %Calculated range for design intensities corresponding to Annual Rainfall Volume CapturedUsed for sizing and performance evaluation of OGS deviceshigh
#P009designtreatmentmandatoryMinimum rainfall events for capture verificationwastewaterrequirement>= 3 eventsVerification of 90% average annual rainfall volume captureIncludes capture of events with rainfall intensity and depth corresponding to 90% average annual rainfall volumehigh

D Definitions (12)

Req ID Category Name Context Confidence
#D001MECPMinistry of Environment, Conservation and Parkshigh
#D002ECAEnvironmental Compliance Approvalhigh
#D003CLI ECAConsolidated Linear Infrastructure Environmental Compliance Approvalhigh
#D004DWWPDrinking Water Works Permithigh
#D005AcceptanceAcceptance items are required post-construction when the infrastructure is put into service. Acceptance is required to start the warranty period.high
#D006AssumptionAssumption items are required at the end of the warranty period in order for the City to assume ownership of the infrastructure.high
#D007ECSEngineering & Construction Serviceshigh
#D008NFPANational Fire Protection Associationhigh
#D009NASSCONational Association of Sewer Service Companieshigh
#D010PACPPipeline Assessment Certification Programhigh
#D011MTDsManufacturer Treatment Deviceshigh
#D012Submission Documentsone digital PDF of the completed Wellness Report including attachmentshigh