Parameter Viewer

Document ID ca-on-r1r9w-2020-01-01 Title R.R.O. 1990, Reg. 903: WELLS URL https://www.ontario.ca/laws/regulation/900903 Jurisdiction /ca/on Subdomain(s) none Language Status completed Analyzed at 2026-05-12 04:04:17.246279+00:00 Relevance inventory_targeted_fetch

Q Qualitative Requirements (52)

Req ID Category Intent Legal Status Name Subdomain(s) Context Conditions Confidence
#Q001designhealthmandatoryLocation Clearancedrinking water, otherThe site of a new well shall be separated, (a) from an earth pit privy, privy vault, pail privy, greywater system or cesspool, as defined in Ontario Regulation 332/12 (Building Code) made under the Building Code Act, 1992, by at least the applicable clearance distance set out in Table 8.2.1.5. of that regulation; and (b) from a treatment unit, distribution pipe or holding tank, as defined in Ontario Regulation 332/12, by at least the applicable clearance distance set out in Table 8.2.1.6.A., 8.2.1.6.B. or 8.2.1.6.C. of that regulation.high
#Q002prohibitionoperationalmandatoryWell Pit Prohibitiondrinking water, otherA new well shall not be constructed with a well pit, and a well pit shall not be added to an existing well, at any location.high
#Q003reportingreportingmandatoryLog and Field Notesdrinking water, otherEvery person constructing or abandoning a well shall make, and have available for inspection at the well site, (a) a log of overburden and bedrock materials; and (b) field notes that include an up-to-date record of the construction or abandonment of the well.high
#Q004operationaloperationalmandatoryCovering of Welldrinking water, otherWhenever a well under construction is left unattended, including during a minor alteration or the installation of a pump, the person constructing the well shall cover the upper open end of the well securely in a manner sufficient to prevent entry into it of surface water and other foreign materials.Whenever a well under construction is left unattendedhigh
#Q005designoperationalmandatorySurface Drainagedrinking water, otherThe person constructing the well shall ensure that the surface drainage is such that water will not collect or pond in the vicinity of the well.high
#Q006operationalhealthmandatoryCasing Cleanlinessdrinking water, otherCasing and well screen shall be clean and free of contamination.high
#Q007designhealthmandatoryCasing Water Quality Protectiondrinking water, otherCasing and well screen shall not impair the quality of water with which it comes in contact.high
#Q008prohibitionoperationalmandatoryLightning Rod Grounding Prohibitiondrinking water, otherNo person shall ground a lightning rod by attaching it, directly or indirectly, to the casing of a well.high
#Q009prohibitionoperationalmandatoryDeepening Prohibitiondrinking water, otherNo person shall construct a well by penetrating through the bottom of a bored or dug well by means of drilling or by the use of a jetted point or driven point.high
#Q010operationaloperationalmandatoryWell Developmentdrinking water, otherBefore the structural stage of a new well is completed, the person constructing the well shall do everything reasonably practicable to remove any debris, including well cuttings and drilling fluids, from the well by developing the well until the well water is clear and free of sand.Before the structural stage of a new well is completedhigh
#Q011administrativereportingmandatoryWell Tag Applicationdrinking water, otherBefore the structural stage of a new cased well is completed, the person constructing the well shall obtain a well tag from the Ministry and shall affix it permanently to the outside of the casing or to a permanent structure associated with the well, at a point where the well tag will be visible and will not be obstructed by the well cap, by other components of the well or by equipment associated with the well.Before the structural stage of a new cased well is completedhigh
#Q012treatmenttreatmentmandatoryDisinfection on Completiondrinking water, otherOn the day the structural stage of the well is completed, the person constructing the well shall ensure that, (a) any remaining debris is removed from the well; (b) the water in the well is dosed to a concentration of not less than 50 milligrams per litre and not more than 200 milligrams per litre of free chlorine and left undisturbed for a period of at least 12 hours; and (c) the water in the well is not used for human consumption until the steps required by subsections (2) to (7) are taken.On the day the structural stage of the well is completedhigh
#Q013prohibitionhealthmandatoryUse Prohibition Before Disinfectiondrinking water, otherNo person shall, during a period between the chlorination of the water in a well by a person referred to in subsection (2) and the testing of the well water for free chlorine residual under this section, (a) disturb the well; or (b) use the well for any purpose.During a period between the chlorination of the water and testinghigh
#Q014designhealthmandatoryVenting Requirementdrinking water, otherIf a new well is constructed by any method, the person constructing the well shall ensure that the well is vented to the outside atmosphere in a manner that will safely disperse all gases.If a new well is constructed by any methodhigh
#Q015prohibitionoperationalmandatoryCutting Torch Prohibitiondrinking water, otherA cutting torch shall not be used to make an opening in the casing wall to accommodate a pitless adapter.high
#Q016reportingreportingmandatoryNotification of Mineralized Waterdrinking water, otherWhere a well is constructed and mineralized water is encountered, the person constructing the well shall immediately notify the well purchaser and the owner of the land on which the well is situated that the condition exists.Where a well is constructed and mineralized water is encounteredhigh
#Q017reportingreportingmandatoryWell Record Reportingdrinking water, otherOn completion of a well’s structural stage, the person constructing the well shall, (a) complete, in accordance with the instructions on the form, a well record for the well; (b) deliver a copy of the well record to the well purchaser and the owner of the land on which the well is situated within 14 days after the date on which the well’s structural stage is complete; (c) forward a copy of the well record to the Director within 30 days after the date on which the well’s structural stage is complete; and (d) retain a copy of the well record for two years.On completion of a well’s structural stagehigh
#Q018operationaloperationalmandatoryWell Maintenancedrinking water, otherThe well owner shall maintain the well at all times after the completion of the well’s structural stage in a manner sufficient to prevent the entry into the well of surface water and other foreign materials.At all times after the completion of the well’s structural stagehigh
#Q019prohibitionoperationalmandatoryCasing Height Reduction Prohibitiondrinking water, otherIf the casing of a well extends above the ground surface, no person shall, (a) reduce the height of the casing, if the casing of the well extends to a height of less than 40 centimetres above the ground surface; or (b) reduce the height of the casing to a height of less than 40 centimetres above the ground surface, if the casing extends to a height of 40 centimetres or more above the ground surface.If the casing of a well extends above the ground surfacehigh
#Q020corrective_actionhealthmandatoryAbandonment of Unused Welldrinking water, otherThe well owner shall immediately abandon the well if it is not being used or maintained for future use as a well.If it is not being used or maintained for future use as a wellhigh
#Q021prohibitionoperationalmandatoryTag Use Limitationdrinking water, otherNo person shall use a well tag obtained from the Ministry, except in accordance with this Regulation.high
#Q022prohibitionoperationalmandatoryTag Removal Prohibitiondrinking water, otherNo person shall remove a well tag affixed in accordance with this Regulation, except, (a) in accordance with subsection 14.11 (3) or (4) or paragraph 1 of subsection 21.1 (1); or (b) with the written consent of the Director.high
#Q023prohibitionoperationalmandatoryTag Defacement Prohibitiondrinking water, otherNo person shall deface, alter, conceal or obstruct a well tag affixed in accordance with this Regulation.high
#Q024designhealthmandatoryResidential Potable Water and Sanitary Facilitiesdrinking water, wastewaterEvery person who owns a residential building shall provide, (a) potable water; and (b) sanitary facilities or a privy, for the residents of the residential building.high
#Q025operationalhealthmandatoryFood Premise Maintenance and OperationotherEvery person who operates a food premise shall maintain and operate the food premise in accordance with the regulations.high
#Q026prohibitionhealthmandatoryProhibition of Scleral Tattooing and Eye JewelleryotherNo person shall sell, offer for sale or provide, any of the following: 1. Scleral tattooing. 2. Implantation of eye jewellery under the conjunctiva.Does not apply to members of a regulated health profession complying with regulationshigh
#Q027reportingreportingmandatoryDisease of Public Health Significance ReportingotherA physician or a practitioner as defined in subsection (2) who, while providing professional services to a person who is not a patient in or an out-patient of a hospital, forms the opinion that the person has or may have a disease of public health significance shall, as soon as possible after forming the opinion, report thereon to the medical officer of health of the health unit in which the professional services are provided.high
#Q028prohibitionunknownmandatoryConfidentiality of Identity in Disease ReportsotherNo person shall disclose to any other person the name of or any other information that will or is likely to identify a person in respect of whom an application, order, certificate or report is made in respect of a communicable disease, a disease of public health significance, a virulent disease or a reportable event following the administration of an immunizing agent.Subject to exceptions listed in Section 39(2)high
#Q029prohibitionoperationalmandatoryProhibition of ObstructionotherNo person shall hinder or obstruct an inspector appointed by the Minister, a medical officer of health, a public health inspector or a person acting under a direction of a medical officer of health lawfully carrying out a power, duty or direction under this Act.Refusal of consent to enter a room used as a dwelling is not considered obstructionhigh
#Q030operationalhealthmandatoryBoard of Health Duty to Provide Programsdrinking water, wastewater, otherEvery board of health shall superintend, provide or ensure the provision of health programs and services in the following areas: 1. Community sanitation, to ensure the maintenance of sanitary conditions and the prevention or elimination of health hazards. 1.1 The provision of safe drinking water by small drinking water systems.high
#Q031administrativereportingmandatoryNotice of Intention to Operate Food PremiseotherEvery person who intends to commence to operate a food premise shall give notice of the person’s intention to the medical officer of health of the health unit in which the food premise will be located.high
#Q032prohibitionoperationalmandatorySewage System Operation CompliancewastewaterNo person shall operate or maintain a sewage system or permit a sewage system to be operated or maintained except in accordance with this Act and the building code.high
#Q033prohibitionoperationalmandatoryBuilding Permit RequirementotherNo person shall construct or demolish a building or cause a building to be constructed or demolished unless a permit has been issued therefor by the chief building official.high
#Q034operationaloperationalmandatoryBuilding Owner Maintenance DutiesotherIt is the role of a building owner, (a) to ensure that the building or part of the building is maintained, repaired and evaluated in accordance with this Act and the building code; and (b) to ensure documents, records and other information about the building are kept and provided in accordance with this Act and the building code.high
#Q035prohibitionoperationalmandatoryOccupancy and Use ProhibitionotherExcept as authorized by the building code, a person shall not occupy or use a building or part of a building that is newly erected or installed or permit it to be occupied or used until the requirements set out in this section are met.Applies to newly erected or installed buildings or parts thereofhigh
#Q036prohibitionoperationalmandatoryObstruction of Officials ProhibitionotherNo person shall hinder or obstruct, or attempt to hinder or obstruct, a chief building official, inspector, officer or a person authorized by a registered code agency in the exercise of a power or the performance of a duty under this Act.high
#Q037operationaloperationalmandatoryDuty to Assist EnforcementotherEvery person shall assist any entry, inspection, examination, testing or inquiry by an inspector, chief building official, officer or a person authorized by a registered code agency in the exercise of a power or performance of a duty under this Act.high
#Q038reportingreportingmandatorySewage System Constructor Notificationwastewaterno person shall begin or continue the construction of a sewage system, or cause it to begin or continue, unless the person has given the chief building official the prescribed information about the specified person [the person undertaking construction].Applies when construction is undertaken by a person requiring specific qualifications/registrationhigh
#Q039reportingreportingmandatoryInsurance Information Reportingotherno person shall begin or continue the construction, or cause it to begin or continue, unless the person has given the chief building official the prescribed information about the specified person and the insurance coverage of the specified person.Applies when construction is undertaken by a person required to have insurancehigh
#Q040administrativereportingmandatoryHigher Value Selection Requirementagricultural waterIf your operation falls in between two values in the column entitled "Portion of Leachate not Reused in Closed Circulation System (GNF)" you must use the higher value.When operation falls in between two listed leachate percentage values in Method 1 Tablehigh
#Q041administrativereportingmandatoryMulti-Operation Aggregation Requirementagricultural waterUsing either method as appropriate, repeat this process for all GNF expected to be generated at each greenhouse operation on the farm unit and add the NUs for each greenhouse operation.When multiple greenhouse operations exist on a single farm unithigh
#Q042administrativereportingmandatoryTotal Farm Unit NU Determinationagricultural waterAdd the NUs for all greenhouse operations on the farm unit to determine the number of nutrient units in the GNF generated on the farm unit in a calendar year.To determine the final farm unit nutrient unit value for registrationhigh
#Q043administrativereportingmandatoryMethod 1 Applicabilityagricultural waterUse this method if generation of GNF is expected from one of the listed greenhouse crops and if the portion of leachate not reused in the closed circulation system is between 3.13 per cent and 50 per cent inclusive.high
#Q044administrativereportingmandatoryCrop Representative Selectionagricultural waterChoose the line in the Table most representative of the crop and the portion of leachate not reused in the closed circulation system. Use this line to determine the values in items C. and D. below.Item C refers to GNF volume and Item D refers to Nutrient Unitshigh
#Q045administrativereportingmandatoryProduction Area Determinationagricultural waterDetermine the greenhouse production area in ha for this crop and circulation systemhigh
#Q046administrativereportingmandatoryMethod 2 Applicabilityagricultural waterUse this method only if the crop grown is not listed in method 1 or if the portion of leachate not reused in the closed circulation system is less than 3.13 per cent or greater than 50 per cent.high
#Q047administrativereportingmandatoryGNF Volume Estimationagricultural waterDetermine the volume (m3) of GNF that you estimate could be generated by a greenhouse in a calendar yearApplicable when using Method 2high
#Q048operationaloperationalmandatoryPhosphorus Load Reduction Targetaquatic life, otherA phosphorus load reduction target of 40% reduction from 2008 levels in phosphorus loadings to the western and central basins for Lake Erie was established and adopted.Western and central basins for Lake Eriehigh
#Q049administrativereportingmandatoryImplementation Team ResponsibilitiesotherThe implementation team is responsible for tracking, assessing and evaluating progress and providing broader engagement opportunities.high
#Q050operationaltreatmentmandatoryMunicipal Sewage and Stormwater ManagementwastewaterThe specific actions the plan commits to include: limiting loadings from municipal sewage treatment plant discharges and better managing stormwater.high
#Q051operationaloperationalguidance4R Nutrient Stewardship Guidanceagricultural waterThe voluntary 4R Nutrient Stewardship program, which encourages producers to use the right source of nutrients at the right rate and the right time in the right place.high
#Q052operationaloperationalguidanceOntario Cover Crops Strategy Guidanceagricultural waterThe implementation of the Ontario Cover Crops Strategy to encourage the widespread adoption of cover crops to protect and improve soil health.high

P Quantitative Requirements (56)

Req ID Category Intent Legal Status Name Subdomain(s) Limit Type Limit Value Context Conditions Confidence
#P001chemicalaestheticmandatoryTotal dissolved solidsdrinking water, agricultural water, otherunknown> 6000 mg/LDefinition of mineralized waterWhen a well produces mineralized water, the owner must be notified and the well immediately abandoned.high
#P002chemicalaestheticmandatoryChloridesdrinking water, agricultural water, otherunknown> 500 mg/LDefinition of mineralized waterWhen a well produces mineralized water, the owner must be notified and the well immediately abandoned.high
#P003chemicalaestheticmandatorySulphatesdrinking water, agricultural water, otherunknown> 500 mg/LDefinition of mineralized waterWhen a well produces mineralized water, the owner must be notified and the well immediately abandoned.high
#P004physicaloperationalmandatoryBentonite solidsotherrequirement>= 20 per cent by weightDefinition of sealantA slurry consisting of clean water and at least 20 per cent bentonite solids by weighthigh
#P005designoperationalmandatoryCasing height above grounddrinking water, agricultural water, otherrequirement>= 40 centimetresA well that obtains water from overburden or bedrock shall be cased from the water intake zone to at least 40 centimetres above the highest point on the ground surface.Does not apply to a well constructed with a well pit pursuant to subsection 12 (8) or specific test holes.high
#P006chemicaltreatmentmandatoryFree chlorinedrinking water, otherrequirement50-200 mg/LDisinfection on completion of structural stage or installation of pumping equipment.The water in the well is dosed to a concentration of not less than 50 mg/L and not more than 200 mg/L of free chlorine and left undisturbed for at least 12 hours.high
#P007chemicaltreatmentmandatoryFree chlorine residualdrinking water, otherrequirement< 1 mg/LRemoval of heavily chlorinated water before human consumption.Water shall be pumped out of the well until the concentration of free chlorine residual in the well water is less than 1 mg/L.high
#P008chemicalhealthmandatoryBenzenedrinking waterMAC0.005 mg/LHealth Related Drinking Water Objective used for groundwater protection design evaluation.Initial source concentration 0.02 mg/L; mass 0.014 mg/kg; half-life 25 years.high
#P009chemicalaestheticmandatoryChloridedrinking waterAO250 mg/LAesthetic Drinking Water Objective for leachate characterization.Initial source concentration varies linearly between 1500-2500 mg/L based on waste loading.high
#P010designoperationalmandatoryInfiltration rate through final coverotherrequirement>= 0.15 m/yearGeneric design options for groundwater protection.Applies to generic designs under subsections 10(4) and 10(5).high
#P011designtreatmentmandatoryAttenuation soil layer thicknessotherrequirement>= 3 metresNatural or engineered layer of soil at the base of the waste fill zone for single liner design.Layer must be relatively homogeneous with hydraulic conductivity <= 1x10-7 m/s.high
#P012designtreatmentmandatoryClayey liner hydraulic conductivityotherrequirement<= 1 × 10-9 m/sPerformance requirement for primary and secondary clayey liners.Must be at least 0.75 metres thick and meet Schedule 4 conditions.high
#P013physicaloperationalmandatoryMethane gas concentration at boundaryotherrequirement< 2.5 per cent by volumeSubsurface migration of landfill gas control.Measured below the surface of the land at the boundary of the site.high
#P014physicaloperationalmandatoryMethane gas concentration in on-site buildingotherrequirement< 1.0 per cent by volumeSafety requirement for enclosed structures containing electrical equipment or ignition sources.Applies inside buildings and immediately outside foundations.high
#P015designtreatmentmandatoryPrimary HDPE geomembrane thicknessotherrequirement>= 1.5 millimetresRequirement for high density polyethylene (HDPE) primary liner.Must meet Schedule 3 conditions for a 150-year service life.high
#P016designtreatmentmandatorySecondary HDPE geomembrane thicknessotherrequirement>= 2.0 millimetresRequirement for high density polyethylene (HDPE) secondary liner.Must meet Schedule 3 conditions for a 350-year service life.high
#P017chemicalhealthmandatoryCadmium Health Objectivedrinking waterMAC0.005 mg/LTable 1 leachate characteristicsInitial source concentration 0.05 mg/L; mass 0.035 mg/kg.high
#P018chemicalhealthmandatoryLead Health Objectivedrinking waterMAC0.01 mg/LTable 1 leachate characteristicsInitial source concentration 0.6 mg/L; mass 0.42 mg/kg.high
#P019physicaloperationalmandatoryMethane gas concentration in off-site buildingotherrequirement< 0.05 per cent by volumeSubsurface migration of landfill gas controlApplies in any off-site building or enclosed structure accessible to any person.high
#P020designoperationalmandatoryBuffer area minimum widthotherrequirement>= 100 metresBuffer area surrounding waste fill areaMust be at least 100 metres wide at every point unless specific conditions for 30 metres are met.high
#P021designoperationalmandatoryMaximum final slopeotherrequirement<= 1:4 unit vertical to units horizontalFinal slopes above grade within the waste fill zone at site closureUnless a report confirms an alternative design is acceptable.high
#P022designoperationalmandatoryMinimum final slopeotherrequirement>= 1:20 unit vertical to units horizontalFinal slopes above grade within the waste fill zone at site closureUnless a report confirms an alternative design is acceptable.high
#P023designoperationalmandatoryFinal cover material minimum thicknessotherrequirement>= 0.6 metresBottom layer of final coverApplied to the waste fill zone.high
#P024designoperationalmandatoryFinal cover topsoil minimum thicknessotherrequirement>= 0.15 metresTopsoil or material able to sustain plant growthApplied as second layer from bottom of final cover.high
#P025operationaloperationalmandatoryTotal waste disposal volume thresholdotherrequirement> 40000 cubic metresApplication of regulationSite intended to accept only municipal waste for disposal.high
#P026chemicalhealthmandatoryDichloro-methanedrinking waterMAC0.05 mg/LHealth Related Drinking Water ObjectiveUsed for evaluating groundwater protection design; initial source concentration 3.3 mg/L.high
#P027chemicalhealthmandatoryVinyl Chloridedrinking waterMAC0.002 mg/LHealth Related Drinking Water ObjectiveInitial source concentration 0.055 mg/L; half-life 25 years.high
#P028chemicalaestheticmandatory1,4 Di-chlorobenzenedrinking waterAO0.001 mg/LAesthetic Drinking Water ObjectiveInitial source concentration 0.01 mg/L; half-life 50 years.high
#P029chemicalaestheticmandatoryToluenedrinking waterAO0.024 mg/LAesthetic Drinking Water ObjectiveInitial source concentration 1.0 mg/L; half-life 15 years.high
#P030operationaloperationalmandatoryLandfill gas collection thresholdotherrequirement> 1500000 cubic metresMandatory gas collection and burning facilitiesApplies to sites with total waste disposal volume exceeding this value.high
#P031designtreatmentmandatoryAttenuation layer hydraulic conductivityotherrequirement<= 1 &times; 10-7 metres per secondBase attenuation layer for generic designLayer must be natural or engineered soil and relatively homogeneous.high
#P032operationalreportingmandatoryChange in ownership notification timeframeotherrequirement30 daysNotification of change in identity, status, or ownership.Within 30 days after any change.high
#P033designoperationalmandatoryReduced buffer area minimum widthotherrequirement>= 30 metresMinimum width of buffer area if specific operational space and impact criteria are met.Must be at least 30 metres wide at every point and confirmed by a written report.high
#P034designtreatmentmandatoryPrimary leachate collection stone layer thicknesswastewaterrequirement>= 0.5 metresContinuous layer of stones across the base for 100-year service life.Excludes base side slopes where 0.3 metres is required.high
#P035designtreatmentmandatoryLeachate stone D85 diameterwastewaterrequirement>= 37 millimetresGrading requirement for stones in the leachate collection system.high
#P036designtreatmentmandatoryLeachate pipe internal diameterwastewaterrequirement>= 150 millimetresMinimum internal diameter for perforated HDPE collection pipes.high
#P037designtreatmentmandatoryLeachate pipe perforation diameterwastewaterrequirement>= 12 millimetresMinimum size for pipe perforations to ensure hydraulic capacity and minimize blockage.high
#P038operationaloperationalmandatoryMinimum contaminating life span estimatewastewaterrequirement>= 25 yearsEstimation of costs for financial assurance related to leachate.Measured from the date waste is last deposited at the site.high
#P039operationalreportingmandatoryOperations record retention periodotherrequirement>= 2 yearsRetention of daily records of site operations.Retained for at least two years after they are made.high
#P040operationalreportingmandatoryAnnual report preparation deadlineotherrequirement3 monthsTiming for the preparation of the annual operations report.Within three months after each anniversary of the date waste was first accepted.high
#P041designtreatmentmandatoryClayey liner lift thicknessotherrequirement<= 0.15 metresCompacted thickness for each lift in a clayey liner.Used for liners meeting Schedule 4 unlimited service life.high
#P042designoperationalmandatoryShallow works depth limitotherrequirement<= 3.0 metresExemption for test holes or dewatering wellsDepth measured below the ground surface; does not apply if it penetrates through a formation that is not an aquifer.high
#P043designhealthmandatoryDrilled well separation distancedrinking waterrequirement>= 15 metresDistance from a source of contaminantsApplies to new drilled wells with casing extending to a depth of more than six metres below ground level.high
#P044designhealthmandatoryOther well separation distancedrinking waterrequirement>= 30 metresDistance from a source of contaminantsApplies to new drilled wells with casing <= 6m or wells that are not drilled.high
#P045operationalreportingmandatoryWell record delivery timeframeotherrequirement14 daysDelivery of well record to purchaser and land ownerWithin 14 days after the date on which the well’s structural stage is complete.high
#P046operationalreportingmandatoryWell record submission to Directorotherrequirement30 daysForwarding copy of well record to the DirectorWithin 30 days after the date on which the well’s structural stage is complete.high
#P047designoperationalmandatoryAbandonment barrier surface seal thicknessotherrequirement50-150 centimetresSealing well at ground surface during abandonmentVertical thickness of bentonite chips, pellets, granules or powder.high
#P048designoperationalmandatoryBoring diameter offset (shallow)otherrequirement>= 15.2 centimetresAnnular space for bored wells with concrete casingDiameter must be this much greater than the outside diameter of casing from ground surface to 2.5m depth.high
#P049designoperationalmandatoryBoring diameter offset (deep)otherrequirement>= 7.6 centimetresAnnular space for bored wells with concrete casingDiameter must be this much greater than the outside diameter of casing from 2.5m to full depth or 6m.high
#P050operationaloperationalmandatoryRecovery of expenses by board of healthotherrequirement> 60 daysTime after demand for payment before secretary transmits statement to municipal clerk for collection.Costs and expenses of a board of health that may be recovered from the owner or occupier of premises.high
#P051operationalreportingmandatoryMOH reporting to Ministry and Agencyotherrequirement<= 7 daysTimeline for MOH to report receiving a report concerning a reportable event under section 38.high
#P052operationaloperationalmandatoryBoard of Health composition (Municipal members)otherrequirement3 to 13 membersNumber of municipal members for each board of health.Does not apply to specific regional municipalities or single-tier municipalities listed in 49(9).high
#P053operationaloperationalmandatoryOffence penalty (Individual)otherrequirement<= 5000 dollarsFine per day for every person guilty of an offence under the Act.high
#P054operationaloperationalmandatoryOffence penalty (Corporation)otherrequirement<= 25000 dollarsMaximum penalty per day for a board of health, municipality, or corporation convicted of an offence.high
#P055operationaloperationalmandatorySearch warrant validity periodotherrequirement<= 15 daysExpiry date of a warrant issued by a justice of the peace under section 43.Date of expiry must be not later than fifteen days after the warrant is issued.high
#P056operationaloperationalmandatoryHearing request timelineotherrequirement<= 15 daysTimeframe to request a hearing by the Board after an order is served.high

D Definitions (14)

Req ID Category Name Context Confidence
#D001Environmental Activity and Sector Registry (EASR)An online registry that allows businesses to register certain activities that are well managed by meeting a standard set of requirements or established outcomes.high
#D002EASR registrationA type of environmental permission that gives businesses permission to operate if they follow standard activity requirements.high
#D003Environmental Protection Act (EPA)Environmental Protection Acthigh
#D004Environmental Compliance Approval (ECA)Environmental Compliance Approvalhigh
#D005Permit to Take Water (PTTW)Permit to Take Waterhigh
#D006EPAEnvironmental Protection Acthigh
#D007ECAEnvironmental Compliance Approvalhigh
#D008PTTWPermit to Take Waterhigh
#D009IItwohigh
#D010ECAsEnvironmental Compliance Approvalhigh
#D011Teltelephonehigh
#D012EASREnvironmental Activity and Sector Registryhigh
#D013transition timelinethe deadline by which you are required to register your activity in the EASR.high
#D014electronic confirmation of registrationyour proof of registration and is required before starting or continuing your activity.high