Parameter Viewer

Document ID ca-on-pgmn-2024-02-01 Title Provincial Groundwater Monitoring Network URL https://data.ontario.ca/dataset/provincial-groundwater-monitoring-network Jurisdiction /ca/on Subdomain(s) none Language Status completed Analyzed at 2026-05-12 03:42:34.418249+00:00 Relevance inventory_targeted_fetch

Q Qualitative Requirements (0)

No qualitative requirements.

P Quantitative Requirements (6)

Req ID Category Intent Legal Status Name Subdomain(s) Limit Type Limit Value Context Conditions Confidence
#R001operationaloperationalmandatoryFoundation drainage water taking limitotherrequirement<= 379,000 litres per dayAll foundation drainage systems used to maintain dry building foundationsRequirement to be exempt from a Permit to Take Water (PTTW)high
#R002chemicaloperationalmandatoryStop log lifter NOx emission limitotherrequirement< 9.2 grams of nitrogen oxides per kWhEquipment (e.g., stop log lifters) used to manage water levels at a dam that uses propane or natural gasRequirement to be exempt from ECA or EASR registrationhigh
#R003designoperationalmandatoryPrivate sewers residential property limitwastewaterrequirement<= 5 residential propertiesPrivate sewers servicing residential properties that discharge to a municipal sewer service connectionRequirement to be exempt from ECA or EASR registrationhigh
#R004designoperationalmandatoryStorm water management works service limitwastewaterrequirement1 lot or parcel of non-industrial landStorm water management works designed to service land discharging to a conveyance ditchRequirement for exemption from Environmental Compliance Approval or EASR registrationhigh
#R005designoperationalmandatorySanitary sewage pumping station service limitwastewaterrequirement1 lot or parcel of landSanitary sewage pumping stations that discharge to a sanitary sewerRequirement for exemption from Environmental Compliance Approval or EASR registrationhigh
#R006designoperationalmandatoryDiesel stop log lifter emission standardotherrequirementTier 1 Emission StandardsEquipment (e.g., stop log lifters) used to manage water levels by adding or removing logs at a dam that uses diesel or biodieselRequirement for exemption from Environmental Compliance Approval (ECA) or EASR registrationhigh

D Definitions (0)