Parameter Viewer

Document ID ca-mb-shcldwtl-2012-06-07 Title Suncrest Holding Co. Ltd. Domestic Wastewater Treatment Lagoon URL https://www.gov.mb.ca/sd/eal/archive/2012/summaries/5565.pdf Jurisdiction /ca/mb Subdomain(s) Wastewater Treatment, Permitting, Zoning & Urban Planning Language en Status completed Analyzed at 2026-03-25 22:27:16.945384+00:00 Relevance Contains specific effluent discharge limits and regulatory requirements for a lagoon.

Q Qualitative Requirements (10)

Req ID Category Intent Legal Status Name Subdomain(s) Context Conditions Confidence
#Q001administrativeunknownmandatoryCompliance with Water Quality RegulationswastewaterThe Licencee is required to comply with the Manitoba Water Quality Standards, Objectives and Guidelines Regulation under The Water Protection Act, including achieving the following effluent discharge limits:high
#Q002operationaloperationalmandatoryTrickle Discharge ImplementationwastewaterThe Licencee shall implement trickle discharge at a rate of 0.006 m 3 /sec over a 27-day period during non-flood conditions.during non-flood conditionshigh
#Q003administrativeoperationalmandatoryWater Rights Licence ApplicationwastewaterPrior to beginning drain construction, the Licencee is required to submit an application for a Water Rights Licence to Construct Water Control Works.Prior to beginning drain constructionhigh
#Q004administrativeoperationalmandatoryWatershed Management ParticipationwastewaterThe Licencee shall actively participate in any future watershed based management study, plan/or nutrient reduction program, approved by the Director.approved by the Directorhigh
#Q005treatmenttreatmentrecommendedSodium Adsorption Ratio ReductionwastewaterThe Water Stewardship Division recommends for the proponent to implement actions to reduce the sodium adsorption ratio in their wastewater.high
#Q006reportingreportingrecommendedAlternative Water Softening Exploration and ReportingwastewaterThe proponent should explore alternative water softening options and report back to the Director, Environmental Assessment and Licensing Branch, in one year.in one yearhigh
#Q007monitoringoperationalmandatorySodium Adsorption Ratio MonitoringwastewaterMonitoring of the Sodium Adsorption Ratio will be performed to determine the anticipated level at discharge.high
#Q008operationaloperationalmandatoryDischarge CoordinationwastewaterIn order to avoid a simultaneous discharge with the Kleefeld wastewater treatment lagoon it is proposed that the operator/manager of the Suncrest facility will communicate directly with the operator/manager of the Kleefeld facility in order to coordinate their discharges.high
#Q009treatmenttreatmentmandatoryChlorination RestrictionwastewaterChlorination will only be used as a last resort in the event that the conform MPN limit cannot be achieved prior to requiring a discharge event.in the event that the conform MPN limit cannot be achieved prior to requiring a discharge eventhigh
#Q010treatmenttreatmentmandatoryChlorination MinimizationwastewaterIn the event that chlorination is required, the amount added will be minimized in order to reduce the residual effects.In the event that chlorination is requiredhigh

P Quantitative Requirements (9)

Req ID Category Intent Legal Status Name Subdomain(s) Limit Type Limit Value Context Conditions Confidence
#P001chemicaltreatmentmandatory5-day Biochemical Oxygen Demandwastewaterrequirement<= 25 mg/Leffluent discharge limitsThe Licencee is required to comply with the Manitoba Water Quality Standards, Objectives and Guidelines Regulation under The Water Protection Acthigh
#P002physicaltreatmentmandatoryTotal Suspended Solidswastewaterrequirement<= 25 mg/Leffluent discharge limitsThe Licencee is required to comply with the Manitoba Water Quality Standards, Objectives and Guidelines Regulation under The Water Protection Acthigh
#P003microbiologicalhealthmandatoryFecal Coliformwastewaterrequirement<= 200 MPN/100mLeffluent discharge limitsThe Licencee is required to comply with the Manitoba Water Quality Standards, Objectives and Guidelines Regulation under The Water Protection Acthigh
#P004chemicaltreatmentmandatoryTotal Phosphoruswastewaterrequirement<= 1 mg/Leffluent discharge limitsThe Licencee is required to comply with the Manitoba Water Quality Standards, Objectives and Guidelines Regulation under The Water Protection Acthigh
#P005operationaloperationalmandatoryTrickle discharge ratewastewaterrequirement0.006 m3/secover a 27-day period during non-flood conditionsduring non-flood conditionshigh
#P006operationaloperationalmandatoryTrickle discharge durationwastewaterrequirement27 daystrickle discharge at a rate of 0.006 m3/sec over a 27-day periodduring non-flood conditionshigh
#P007unknownreportingrecommendedSodium adsorption ratio reporting timeframewastewaterrequirement1 yearexplore alternative water softening options and report back to the Directorone year following the recommendationhigh
#P008operationaloperationalmandatoryEffluent discharge season startwastewaterrequirementJune 15 datetrickle discharged between June 15th and November 1stany yearhigh
#P009operationaloperationalmandatoryEffluent discharge season endwastewaterrequirementNovember 1 datetrickle discharged between June 15th and November 1stany yearhigh

D Definitions (0)

No definitions.