Document ID ca-hfnwtsu-2023-03-20-2 Title Hiawatha First Nation Water Treatment System Upgrades URL https://iaac-aeic.gc.ca/050/evaluations/proj/84268 Jurisdiction /ca Subdomain(s) Drinking Water, Groundwater Language en Status completed Analyzed at 2026-04-15 01:39:08.656545+00:00 Relevance backfill_2026_04_12: This document is a project-specific environmental assessment record for a single infrastructure proj

Q Qualitative Requirements (36)

Req ID Category Intent Legal Status Name Subdomain(s) Context Conditions Confidence
#Q001treatmenttreatmentmandatoryPOE System Treatment Processesdrinking waterThe POE systems will utilize a combination of treatment processes involving sediment filters, air injection oxidation filters, granular activated carbon (GAC) filters, cartridge filters, and ion exchange resin to treat groundwater.Applies to Point-of-Entry (POE) systemshigh
#Q002treatmenttreatmentmandatoryPrimary Disinfectiondrinking waterPrimary disinfection will be achieved using ultraviolet irradiation.high
#Q003designoperationalmandatoryPOE System Housingdrinking waterThe POE treatment systems will be housed in an outdoor wooden enclosure and will be built on member-owned land.high
#Q004designoperationalmandatoryService Connection Componentsdrinking waterAll service connections will include a shut-off valve, a water meter, backflow preventor, and a pressure-reducing valve in an accessible location inside the residence.high
#Q005designoperationalmandatoryPipe Penetrations Designdrinking waterPipe penetrations for service connections will be located below the frost line and hydraulically sealed prior to commissioning.high
#Q006operationaloperationalmandatoryExisting Well Decommissioningdrinking waterExisting wells will be decommissioned.Upon implementation of the new water treatment system or drilled wellshigh
#Q007operationaloperationalmandatoryPump Rates Regulationdrinking waterPump rates will be set so as to not exceed the maximum recharge rate of the well.high
#Q008administrativeunknownmandatorySeptic Field Precautions and Mitigationwastewater, drinking waterSeptic fields on private property have also been identified and appropriate precaution/mitigation will be defined with direct communication with the utility owner prior to finalizing any design drawings.Prior to finalizing design drawings where septic fields are presenthigh
#Q009designtreatmentrecommendedPretreatment Minimum RequirementwastewaterLes procédés de traitement biologique mécanisés devraient être précédés à tout le moins d'un dégrilleur.Standard mechanized biological treatment installationshigh
#Q010designtreatmentrecommendedBioreactor Design BasiswastewaterLes bioréacteurs devraient être conçus en fonction des charges journalières moyennes de DBO5C, NTK et Ptot et du débit journalier moyen.high
#Q011designoperationalrecommendedSeasonal Performance VerificationwastewaterLe concepteur devrait donc vérifier sa conception pour les conditions hivernales et printanières.Applies to biomass activity slowdown below 15°Chigh
#Q012designoperationalrecommendedSludge Management IntegrationwastewaterOn devrait donc intégrer à la filière de traitement un système de gestion des boues secondaires.high
#Q013designtreatmentrecommendedMass Balance Return LoadswastewaterLe bilan massique effectué devrait tenir compte des charges présentes dans ces eaux retournées en tête de traitement en plus des charges de l'affluent.When sludge treatment produces supernatants or filtrates returned to the liquid streamhigh
#Q014operationaltreatmentrecommendedDissolved Oxygen Level - NitrificationwastewaterDans un procédé de nitrification, le système d'aération devrait maintenir la concentration d'oxygène dissous dans le bioréacteur à un minimum de 2 mg O2/l en tout temps (incluant les pointes).Nitrification processeshigh
#Q015designoperationalrecommendedAeration Equipment RedundancywastewaterLe concepteur devrait prévoir les équipements d'aération (soufflantes ou surpresseurs) de façon à pouvoir répondre à la demande maximale en oxygène même si la plus grosse unité est à l'arrêt.N-1 redundancy for maximum oxygen demandhigh
#Q016designoperationalrecommendedMBR Reliability StandardwastewaterL'installation devrait être en mesure de traiter le débit maximal instantané avec 10 % des modules hors service.Membrane Biological Reactor (MBR) systemshigh
#Q017administrativeoperationalmandatoryOperator Qualification RequirementswastewaterL'exploitant doit avoir une formation adéquate et posséder de bonnes connaissances du procédé de traitement, en chimie, en microbiologie, en électricité, en instrumentation et contrôle ainsi qu'en mécanique.Mechanized wastewater treatment plant operationhigh
#Q018designoperationalrecommendedSBR Peak Flow RedundancywastewaterLe volume alloué à l'affluent à l'étape de décantation devrait être suffisant pour admettre 75 % du débit journalier maximal avec la plus grande unité hors service, et ce, sans changer la durée des cycles.SBR systems with one unit out of servicehigh
#Q019designtreatmentrecommendedSBR Clarified Water BufferwastewaterIl est recommandé de conserver, au-dessus du voile de boues, une hauteur tampon d'eau clarifiée d'au moins 0,5 m pour éviter l'entraînement de boues avec l'effluent.SBR settling phasehigh
#Q020designoperationalmandatorySBR Effluent Withdrawal Velocitywastewaterla vitesse maximale d'entraînement à sa bouche ne devrait pas dépasser 3 m/s.SBR effluent withdrawal devicehigh
#Q021designoperationalrecommendedSBR Mixing CapabilitywastewaterLe système devrait être en mesure de mélanger complètement le réacteur en 5 minutes à partir d'un état décanté, et ce, sans l'aide de l'aération.SBR mixing systemshigh
#Q022designtreatmentrecommendedMBR Pretreatment Fine ScreeningwastewaterPour protéger les membranes de filtration contre les débris qui pourraient les endommager, on devrait effectuer un dégrillage fin de l'affluent en plus du dégrillage grossier.MBR installationshigh
#Q023operationaloperationalmandatoryMBR Membrane Handling TemperaturewastewaterLeur manipulation devrait se faire en tout temps à l'intérieur d'un bâtiment.MBR membrane modules (must not be subjected to temperatures below 5°C)high
#Q024monitoringreportingrecommendedMBR Monitoring and Alarmswastewatertous les paramètres importants devraient être suivis, enregistrés en continu et liés à des alarmes comme : le niveau d'eau dans les bassins, le différentiel de pression entre l'amont et l'aval des membranes, les débits de perméat sur chaque train, la température de l'eau, les vitesses des variateurs de fréquence des équipements asservisMBR proactive managementhigh
#Q025designoperationalrecommendedBasin Freeboard - Mechanical AeratorswastewaterLes bassins d'aération devraient avoir une revanche d'au moins 0,5 m et d'au moins 0,9 m si l'on utilise des aérateurs de surface formant des aérosols.Activated sludge aeration basinshigh
#Q026designoperationalrecommendedSBR Scum PreventionwastewaterIl devrait être conçu de façon à prévenir l'entraînement des écumes ou des matières flottantes.SBR effluent withdrawal devicehigh
#Q027designoperationalrecommendedMBR Scum ManagementwastewaterOn devrait envisager des dispositifs tels qu'un système d'aspersion de produits antimoussants ou des gicleurs pour éviter son accumulation en surface.MBR reactors prone to foam productionhigh
#Q028monitoringoperationalmandatoryBiomass Quality MonitoringwastewaterCette dernière peut être vérifiée régulièrement en mesurant l'indice de volume de boues (ou indice de Mohlman) et en observant divers indices comme la couleur de la liqueur mixte, la présence et les caractéristiques de la mousse ou l'état de floculation.Activated sludge process operationhigh
#Q029administrativereportingrecommendedOperation Manual PreparationwastewaterOn devrait préparer un manuel d'exploitation complet, adapté aux équipements installés.high
#Q030designoperationalrecommendedPeak Factor Design VerificationwastewaterLe concepteur devrait toutefois porter une attention particulière aux facteurs de pointe et vérifier la conception du système pour assurer l'efficacité du traitement lors des pointes courtes (horaire) et soutenues (p. ex. moyenne de 30 jours).high
#Q031designtreatmentrecommendedSecondary Clarifier Mass Loading CheckwastewaterLe concepteur devrait s'assurer que le décanteur secondaire est en mesure de traiter la charge massique en MES attendue au débit moyen et lors des pointes.high
#Q032designtreatmentrecommendedTotal Oxygen Demand CalculationwastewaterLa demande totale en oxygène devrait être calculée pour la pointe de charge prévue (WEF et ASCE/EWRI, 2018).high
#Q033designoperationalrecommendedSBR Mixed Liquor RedirectionwastewaterOn devrait aussi prévoir un système permettant de rediriger la liqueur mixte emprisonnée dans le dispositif d'évacuation à l'étape de réaction pour éviter une dégradation de l'effluent.high
#Q034designoperationalrecommendedMBR Equipment Provision in DesignwastewaterTous les équipements mécaniques et accessoires requis pour effectuer le nettoyage des membranes, le suivi et l'entretien du RBM devraient être prévus dans les plans et devis.high
#Q035administrativeoperationalrecommendedExpert Operating Contract RequirementwastewaterDans le cas d'une très petite station où l'expertise du propriétaire ou de la municipalité est parfois limitée, on devrait confier à un expert un contrat d'exploitation (ou d'assistance à l'exploitation).Very small stations with limited local expertisehigh
#Q036operationaloperationalrecommendedRecirculation Issue Resolution DutywastewaterTout colmatage ou autre problème de recirculation de boues devrait être réglé sans délai.high

P Quantitative Requirements (38)

Req ID Category Intent Legal Status Name Subdomain(s) Limit Type Limit Value Context Conditions Confidence
#P001designoperationalmandatoryPiping diameterdrinking waterrequirement25 mm11 watermain service connections will be installed to provide access to potable water to residents of the community. These connections will consist of 25mm piping.Applies to watermain service connectionshigh
#P002operationaltreatmentrecommendedMinimum Dissolved Oxygen for NitrificationwastewaterOG>= 2 mg O2/lDans un procd de nitrification, le systme d'aration devrait maintenir la concentration d'oxygne dissous dans le bioracteur un minimum de 2 mg O2/l en tout temps.During nitrification processes, including peak loadshigh
#P003operationaltreatmentrecommendedTypical Winter Sludge Retention Time (TRB) - Classic Activated SludgewastewaterOG15 dEn pratique, le TRB vis pour les boues actives classiques est typiquement de 15 jours en saison hivernale.Winter season operationhigh
#P004designoperationalrecommendedRecommended Water Level for Activated Sludge ReactorswastewaterOG3.5 - 5 mLe niveau d'eau dans les racteurs devrait tre au-dessus de 3 m, mais infrieur 9 m. Celui recommand varie typiquement entre 3,5 et 5 m.Classic activated sludge bioreactorshigh
#P005designtreatmentrecommendedMBR Fine Screening Openingwastewaterrequirement0.5 - 2 mmPour protger les membranes de filtration contre les dbris qui pourraient les endommager, on devrait effectuer un dgrillage fin de l'affluent... On recommande des ouvertures de 0,5 mm 2 mm.Pretreatment for membrane bioreactors (RBM)high
#P006designtreatmentrecommendedCarbonaceous Oxygen Demand (AORC) for Extended AerationwastewaterOG1.5 g O2/g DBO5CPour les boues activées à aération prolongée, la demande à retenir est plutôt de 1,5 g O2/g DBO5C, ce qui inclut les besoins liés à la respiration endogène.Applicable to extended aeration (AP) processeshigh
#P007designoperationalmandatoryMechanical Aeration Mixing Power for MLSS Suspensionwastewaterrequirement16 - 25 W/m³Puissance de mélange requise pour assurer la concentration uniforme de MSLM (< 6 000 mg/l) avec aération mécanique.Mechanical aeration systems for MLSS concentrations under 6000 mg/lhigh
#P008designoperationalmandatoryOxidation Ditch Circulation Velocitywastewaterrequirement0.3 m/sLa liqueur mixte est maintenue en mouvement circulaire dans les fossés à une vitesse de l'ordre de 0,3 m/s, ce qui est suffisant pour garder la biomasse en suspension.Operation of oxidation ditch processeshigh
#P009chemicalhealthmandatoryStandard Effluent DBO5 and MES Concentrationwastewaterrequirement25 mg/lDans l'ensemble, on peut respecter une moyenne périodique (de trois résultats ou plus) à l'effluent de 25 mg/l de DBO5 et de MES.Compliance target for activated sludge plants with decanters in Quebechigh
#P010designtreatmentrecommendedMBR Typical Net Filtration FluxwastewaterOG25 L.m-2.h-1Actuellement, l'exploitation à des flux nets d'environ 25 L.m-2.h-1 est privilégiée dans le cas du traitement d'eaux usées municipales.Submerged MBR systems for municipal wastewater at 20°Chigh
#P011designtreatmentrecommendedStandard Nitrification Oxygen Demand (AORN)wastewaterOG4.6 g O2/g NTKL'AORN est d'environ 4,6 g O2/g NTK (MOE, 2008).Standard nitrification oxygen requirement calculationhigh
#P012designtreatmentmandatoryVolumetric Load - Classic Activated Sludge (CSTR)wastewaterrequirement0.3 - 1.6 kg DBO5.m-³.d-1Charge volumétrique pour le procédé de boues activées classiques (Réacteur complètement mélangé).Design for completely mixed classic activated sludge reactorhigh
#P013designtreatmentmandatoryHydraulic Retention Time (TRH) - Classic Activated Sludge (CSTR)wastewaterrequirement3 - 6 hTRH à Qmoy pour le procédé de boues activées classiques (Réacteur complètement mélangé).Design flow (Qmoy)high
#P014operationaloperationalrecommendedTypical MBR MLSS ConcentrationwastewaterOG8000 - 10000 mg/lla concentration des MSLM visée dans le RBM est généralement autour de 8 000 à 10 000 mg/l.Typical operational range for Membrane Bioreactorshigh
#P015designtreatmentmandatoryMinimum RBS Operating Heightwastewaterrequirement>= 3.0 mLe volume d'eau minimal dans un RBS à la fin de l'étape du soutirage du surnageant... La hauteur d'eau correspondante devrait être de 3,0 m ou plus.At the end of the decant (effluent removal) stagehigh
#P016designtreatmentrecommendedTypical Selector Contact Time (TRH)wastewaterOG20 - 60 minle volume total d'un sélecteur assure généralement un TRH de l'ordre de 20 à 60 minutes sur la base du débit moyen d'affluent.Municipal wastewater treatment using selector zoneshigh
#P017designtreatmentrecommendedAeration Capacity Peak Factor for DBO5CwastewaterOG>= 2 unitlessUn facteur de pointe d'au moins 2 est généralement appliqué à la charge moyenne de DBO5C pour calculer la capacité maximale du système d'aération.Applicable to average carbonaceous loadhigh
#P018designoperationalrecommendedAnoxic Zone Mixing PowerwastewaterOG3 - 8 W/m³La puissance de mélange requise dans une zone anoxique pour la dénitrification varie typiquement entre 3 W/m³ pour les mélangeurs à faible vitesse et 8 W/m³ pour ceux à haute vitesse.Dependent on mixer type (low speed vs high speed)high
#P019designoperationalrecommendedStandard Freeboard - Activated Sludgewastewaterrequirement>= 0.5 mLes bassins d'aération devraient avoir une revanche d'au moins 0,5 m.Standard aeration basins; increases to 0.9 m for surface aeratorshigh
#P020physicaltreatmentrecommendedMinimum Design Temperature - Snowmeltwastewaterrequirement6 °Cil est recommandé d'envisager une température minimale... d'environ 6 °C lors de la fonte si le réseau véhicule beaucoup d'eaux parasites.Spring snowmelt periods with parasitic water inflowhigh
#P021chemicaltreatmentrecommendedAlkalinity Credit from DenitrificationwastewaterOG3.5 g CaCO3/g N-NO3Augmentation de l'alcalinité nécessaire à la nitrification dans les boues activées (crédit d'environ 3,5 g CaCO3/g N-NO3 denitrifié).Applicable during anoxic denitrificationhigh
#P022designoperationalrecommendedMBR Scouring Air Flow RatewastewaterOG0.2 - 0.8 Nm³.h-1.m-2Il est généralement compris entre 0,2 et 0,8 Nm³.h-1.m-2 de surface de membrane.Air scouring for submerged membraneshigh
#P023designoperationalrecommendedSBR Redundancy Capacitywastewaterrequirement75 %Le volume alloué à l'affluent à l'étape de décantation devrait être suffisant pour admettre 75 % du débit journalier maximal avec la plus grande unité hors service.Decant stage capacity with N-1 unit redundancyhigh
#P024designtreatmentrecommendedMBR Design Peak FactorwastewaterOG2.0 - 2.5 unitlessEn général, les RBM sont conçus pour un facteur de pointe journalier de 2,0 à 2,5 par rapport au débit moyen de conception.Daily peak factor for municipal wastewater RBM designhigh
#P025designoperationalrecommendedMixing Air Flow Rate - Coarse Bubbleswastewaterrequirement0.33 L.m-3.s-1Diffuseurs à grosses bulles: 0,33 L.m-3.s-1 par rapport au volume du réacteur pour concentration uniforme de MSLM.MLSS suspension under 6000 mg/lhigh
#P026operationaltreatmentrecommendedMBR Filtration Tank Dissolved OxygenwastewaterOG2.0 - 6.0 mg/lbassin de filtration : 2,0 à 6,0 mg/l.Operating DO level in MBR membrane tankhigh
#P027operationaltreatmentguidelineSpecific Denitrification Rate (TSD) - Pre-denitrificationwastewaterOG0.04 - 0.25 g NO3-N.g-1 MVES.d-1Tableau 10.3.1-7 présente des valeurs typiques de TSD... Prédénitrification: 0,04 - 0,25.Based on VSS concentration at 20°Chigh
#P028designtreatmentrecommendedMBR Anoxic Volume FractionwastewaterOG20 - 40 %Dans le cas d'un RBM, la zone anoxique peut représenter 20 % à 40 % du volume total du bioréacteur.MBR denitrification design compared to 15-20% for classic sludgehigh
#P029operationaltreatmentguidelineLEM Nitrate Removal Efficiencywastewatertreatment_goal60 - 85 %Généralement, le procédé LEM présente des performances d'enlèvement des nitrates de 60 % à 85 %.Typical performance for Modified Ludzack-Ettinger processhigh
#P030designtreatmentmandatorySBR Minimum Peak Hydraulic Retention Timewastewaterrequirement4 hLe volume devrait également offrir un TRH minimal de 4 h au débit journalier maximal (100 %) malgré l'arrêt du plus grand réacteur.At 100% maximum daily flow with N-1 redundancyhigh
#P031operationaltreatmentrecommendedSummer Sludge Retention Time (TRB) - Classic Activated SludgewastewaterOG6 - 7 dle TRB visé pour les boues activées classiques... peut descendre à 6 ou 7 jours en saison estivale.Summer season operationhigh
#P032operationaloperationalguidelineMBR Flux Temperature Correction FactorwastewaterOG3 %/°Cla littérature rapporte une réduction du flux de 3 % par degré Celsius en dessous de 20 °C.Temperature impact on MR filtration capacityhigh
#P033operationaltreatmentrecommendedMinimum DO for Non-Nitrifying Process (Peak)wastewaterOG0.5 mg O2/lDans un procédé conçu uniquement pour l'enlèvement de la matière organique... Elle peut toutefois descendre jusqu'à 0,5 mg O2/l en période de pointe de charge.Peak load periods in non-nitrifying systemshigh
#P034designtreatmentrecommendedExtended Aeration Sludge Retention Time (TRB)wastewaterOG20 - 40 dTypical sludge retention times for extended aeration processes are significantly longer to ensure stabilization.Applicable to standard extended aeration (AP) process designhigh
#P035designtreatmentrecommendedOxidation Ditch Sludge Retention Time (TRB)wastewaterOG15 - 30 dDesign criteria for oxidation ditches, a variant of extended aeration.Applicable to oxidation ditch configurationhigh
#P036operationaloperationalrecommendedSBR MLSS Concentration RangewastewaterOG2000 - 5000 mg MES/lStandard mixed liquor suspended solids concentration ranges for sequencing batch reactors.Operational range for SBR systemshigh
#P037operationaloperationalguidanceAbsolute Maximum MBR MLSS Concentrationwastewaterrequirement20000 mg/lAu contraire des décanteurs... celle-ci peut atteindre 20 000 mg/l dans les RBM.Upper limit for MBR systems, although typically maintained lower for oxygen transferhigh
#P038chemicaltreatmentguidelineNitrification Half-Saturation Constant for Oxygen (KO,AOB)wastewaterOG0.50 mg O2/lTypical kinetic value used for calculating oxygen impact on nitrification rates.Kinetic parameter for nitrifying bacteriahigh

D Definitions (18)

Req ID Category Name Context Confidence
#D001TRBtemps de rétention des boues (aussi appelé « âge des boues »)high
#D002RBSréacteurs biologiques séquentielshigh
#D003RBMréacteurs biologiques membranaireshigh
#D004BEboues extraites (ou en anglais WAS pour waste activated sludge)high
#D005BRboues recirculées (ou en anglais RAS pour recirculated activated sludge)high
#D006MSLMmatières en suspension dans la liqueur mixtehigh
#D007S/Mrapport substrat/microorganismes (ou en anglais F/M pour food/microorganisms)high
#D008AOBBactéries qui oxydent les NH4+ en nitrites (ammonium oxidizing bacteria)high
#D009LEMprocédé Ludzack-Ettinger modifié (ou en anglais MLE pour Modified Ludzack-Ettinger)high
#D010procédé ABabréviation d'absorption-biodégradationhigh
#D011Membraneélément de filtrationhigh
#D012Moduleensemble de membranes qui forment une seule unité. Celle-ci doit être retirée et remplacée dans son intégralité, le cas échéanthigh
#D013Cassetterassemblement de modules comprenant également la structure de support, la conduite de perméat, les aérateurshigh
#D014Traincombinaison de plusieurs cassettes présentant les conduites principales de perméat et d'alimentation en air. Les trains sont installés en parallèle les uns aux autres et permettent de traiter une partie du débit. Un bassin de filtration correspond à un train.high
#D015CIPclean in placehigh
#D016exploitant municipalUn système d’égout, que ce soit sa totalité ou certaines de ses composantes, peut être exploité par une municipalité, une régie intermunicipale ou une autre entité agissant à titre de concessionnaire pour une ou plusieurs municipalités. Une telle entité est appelée « exploitant municipal ».high
#D017diagnostic d’un système d’égoutun portrait de la situation des débordements et des dérivations au sein d’une municipalité.high
#D018eaux parasiteseaux d’infiltration et eaux de pluiehigh