| #P001 | chemical | reporting | guideline | Selenium | drinking water | unknown | 1.3 µg/L | Method detection limit (MDL) for U.S. EPA Method 200.5 Rev. 4.2 | Employs axially viewed inductively coupled plasma atomic emission spectrometry | high |
| #P002 | chemical | reporting | guideline | Selenium | drinking water | unknown | 7.9 µg/L | Method detection limit (MDL) for U.S. EPA Method 200.8 Rev. 5.4 | Based on inductively coupled plasma mass spectrometry | high |
| #P003 | chemical | reporting | guideline | Selenium | drinking water | unknown | 0.6 µg/L | Method detection limit (MDL) for U.S. EPA Method 200.9 Rev. 2.2 | Uses stabilized temperature platform graphite furnace atomic absorption | high |
| #P004 | chemical | reporting | guideline | Selenium | drinking water | unknown | 5-100 µg/L | Optimum selenium concentration range reported for standard method SM 3113 B | Analysis of selenium using electrothermal atomic absorption | high |
| #P005 | chemical | reporting | guideline | Selenium | drinking water | unknown | 2 µg/L | Estimated detection level for standard method SM 3113 B | Analysis of selenium using electrothermal atomic absorption | high |
| #P006 | chemical | reporting | guideline | Selenium | drinking water | unknown | 2-20 µg/L | Optimum selenium concentration range for standard method SM 3114 B | Manual hydride generation atomic absorption spectrometry method | high |
| #P007 | chemical | reporting | guideline | Selenium | drinking water | unknown | 2 µg/L | Method detection limit (MDL) for standard method SM 3114 B | Manual hydride generation atomic absorption spectrometry method | high |
| #P008 | chemical | reporting | guideline | Selenium | drinking water | unknown | 1-20 µg/L | Applicable range for ASTM D3859 Method A | Gaseous hydride atomic absorption spectrometry | high |
| #P009 | chemical | reporting | guideline | Selenium | drinking water | unknown | 2-100 µg/L | Reported range for ASTM D3859 Method B | Graphite furnace atomic absorption spectrometry | high |
| #P010 | chemical | reporting | guideline | Selenium | drinking water | unknown | 10 µg/L | Current practical quantitation level (PQL) | Based on the capability of laboratories to measure the concentration of selenium within reasonable limits of precision and accuracy | high |
| #P011 | chemical | reporting | guidance | Se(IV) and Se(VI) | drinking water | unknown | 0.01 µg/L | Method detection limit (MDL) each for Se(IV) and for Se(VI) in tap water using a recent experimental method | Using microwave-induced nitrogen plasma mass spectrometry | high |